<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-13 19-31-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 5.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 60 kHz 14167 5,0681
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,5 dBr 2,83 dBr 3,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 60 kHz MIN: 14 kHz % above 76 kHz: 5,0681 Acquired: 2024/08/13 19.30.06 Total samples: 14167 Equivalent time: 0:11:48 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 3,6 dBr MIN: 0,5 dBr AVE: 2,83 dBr % above 12,2 dBr: 0,0 Last value: 2,5 dBr (2024/08/13 19.30.05) 19.16 19.18 19.20 19.22 19.24 19.26 19.28 19.30 -1 0 1 2 3 4 Pm [dBr]